2,040 research outputs found

    Measured pedestrian movement and bodyworn terminal effects for the indoor channel at 5.2 GHz

    Get PDF
    [Summary]: Human body effects such as antenna-body interaction and scattering caused by pedestrian movement are important indoor radio propagation phenomena at microwave frequencies. This paper reports measurements and statistical analysis of the indoor narrowband propagation channel at 5.2 GHz for two scenarios: a fixed line-of-sight (LOS) link perturbed by pedestrian movement and a mobile link incorporating a moving bodyworn terminal. Two indoor environments were considered for both types of measurements: an 18 m long corridor and a 42 m2 office. The fixed-link results show that the statistical distribution of the received envelope was dependent on the number of pedestrians present. However, fading was slower than expected, with an average fade duration of more than 100 ms for a Doppler frequency of 8.67 Hz. For the bodyworn terminal, mean received power values were dependent on whether or not the user's body obstructed the LOS. For example, in the corridor the average non-line-of-sight (NLOS) pathloss was 5.4 dB greater than with LO

    Defining Markets That Involve Multi-Sided Platform Businesses: An Empirical Framework With an Application to Google's Purchase of DoubleClick

    Get PDF
    A multi-sided platform (MSP) serves as an intermediary for two or more groups of customers who are linked by indirect network effects. Recent research has found that MSPs are significant in many industries and that some standard economic results, such as the Lerner Index, do not apply to them, in material ways, without some significant modification to take linkages between the multiple sides into account. This article extends several key tools used for the analysis of mergers to situations in which one or more of the suppliers are MSPs. It shows that the application of traditional tools to mergers involving MSPs results in biases the direction of which depends on the particular tool being used and other conditions. It also extends these tools to the analysis of the merger of MSPs. The techniques are illustrated with an application to an acquisition by Google in the online advertising industry.

    2. dokumentum : Macedónia : az osztrák-orosz reformok

    Get PDF

    Proteostasis by STUB1/HSP70 complex controls sensitivity to androgen receptor targeted therapy in advanced prostate cancer.

    Get PDF
    Protein homeostasis (proteostasis) is a potential mechanism that contributes to cancer cell survival and drug resistance. Constitutively active androgen receptor (AR) variants confer anti-androgen resistance in advanced prostate cancer. However, the role of proteostasis involved in next generation anti-androgen resistance and the mechanisms of AR variant regulation are poorly defined. Here we show that the ubiquitin-proteasome-system (UPS) is suppressed in enzalutamide/abiraterone resistant prostate cancer. AR/AR-V7 proteostasis requires the interaction of E3 ubiquitin ligase STUB1 and HSP70 complex. STUB1 disassociates AR/AR-V7 from HSP70, leading to AR/AR-V7 ubiquitination and degradation. Inhibition of HSP70 significantly inhibits prostate tumor growth and improves enzalutamide/abiraterone treatments through AR/AR-V7 suppression. Clinically, HSP70 expression is upregulated and correlated with AR/AR-V7 levels in high Gleason score prostate tumors. Our results reveal a novel mechanism of anti-androgen resistance via UPS alteration which could be targeted through inhibition of HSP70 to reduce AR-V7 expression and overcome resistance to AR-targeted therapies

    Accounting for Uncertainties in Strengths of SiC MEMS Parts

    Get PDF
    A methodology has been devised for accounting for uncertainties in the strengths of silicon carbide structural components of microelectromechanical systems (MEMS). The methodology enables prediction of the probabilistic strengths of complexly shaped MEMS parts using data from tests of simple specimens. This methodology is intended to serve as a part of a rational basis for designing SiC MEMS, supplementing methodologies that have been borrowed from the art of designing macroscopic brittle material structures. The need for this or a similar methodology arises as a consequence of the fundamental nature of MEMS and the brittle silicon-based materials of which they are typically fabricated. When tested to fracture, MEMS and structural components thereof show wide part-to-part scatter in strength. The methodology involves the use of the Ceramics Analysis and Reliability Evaluation of Structures Life (CARES/Life) software in conjunction with the ANSYS Probabilistic Design System (PDS) software to simulate or predict the strength responses of brittle material components while simultaneously accounting for the effects of variability of geometrical features on the strength responses. As such, the methodology involves the use of an extended version of the ANSYS/CARES/PDS software system described in Probabilistic Prediction of Lifetimes of Ceramic Parts (LEW-17682-1/4-1), Software Tech Briefs supplement to NASA Tech Briefs, Vol. 30, No. 9 (September 2006), page 10. The ANSYS PDS software enables the ANSYS finite-element-analysis program to account for uncertainty in the design-and analysis process. The ANSYS PDS software accounts for uncertainty in material properties, dimensions, and loading by assigning probabilistic distributions to user-specified model parameters and performing simulations using various sampling techniques

    Fracture Strength of Single-Crystal Silicon Carbide Microspecimens at Room and Elevated Temperature

    Get PDF
    Three shapes of tensile specimens were tested--curved with a very low stress concentration factor and straight with either a circular hole or an elliptical hole. The nominal thickness was 125 micron with a net section 100 micron wide; the overall length of these microspecimens was 3.1 mm. They were fabricated by an improved version of deep reactive ion etching, which produced specimens with smooth sidewalls and cross-sections having a slightly trapezoidal shape that was exaggerated inside the holes. The novel test setup used a vertical load train extending into a resistance furnace. The specimens had wedge-shaped ends which fit into ceramic grips. The fixed grip was mounted on a ceramic post, and the movable grip was connected to a load cell and actuator outside the furnace with a ceramic-encased nichrome wire. The same arrangement was used for tests at 24 and at 1000 C. The strengths of the curved specimens for two batches of material (made with slightly different processes) were 0.66+/-0.12 GPa and 0.45+/-0.20 GPa respectively at 24 C with identical values at 1000 C. The fracture strengths of the circular-hole and elliptical-hole specimens (computed from the stress concentration factors and measured loads at failure) were approximately 1.2 GPa with slight decreases at the higher temperature. Fractographic examinations showed failures initiating on the surface--primarily at corners. Weibull predictions of fracture strengths for the hole specimens based on the properties of the curved specimens were reasonably effective for the circular holes, but not for the elliptical holes

    Fabrication and Probabilistic Fracture Strength Prediction of High-Aspect-Ratio Single Crystal Silicon Carbide Microspecimens With Stress Concentration

    Get PDF
    Single crystal silicon carbide micro-sized tensile specimens were fabricated with deep reactive ion etching (DRIE) in order to investigate the effect of stress concentration on the room-temperature fracture strength. The fracture strength was defined as the level of stress at the highest stressed location in the structure at the instant of specimen rupture. Specimens with an elliptical hole, a circular hole, and without a hole (and hence with no stress concentration) were made. The average fracture strength of specimens with a higher stress concentration was larger than the average fracture strength of specimens with a lower stress concentration. Average strength of elliptical-hole, circular-hole, and without-hole specimens was 1.53, 1.26, and 0.66 GPa, respectively. Significant scatter in strength was observed with the Weibull modulus ranging between 2 and 6. No fractographic examination was performed but it was assumed that the strength controlling flaws originated from etching grooves along the specimen side-walls. The increase of observed fracture strength with increasing stress concentration was compared to predictions made with the Weibull stress-integral formulation by using the NASA CARES/Life code. In the analysis isotropic material and fracture behavior was assumed - hence it was not a completely rigorous analysis. However, even with these assumptions good correlation was achieved for the circular-hole specimen data when using the specimen data without stress concentration as a baseline. Strength was over predicted for the elliptical-hole specimen data. Significant specimen-to-specimen dimensional variation existed in the elliptical-hole specimens due to variations in the nickel mask used in the etching. To simulate the additional effect of the dimensional variability on the probabilistic strength response for the single crystal specimens the ANSYS Probabilistic Design System (PDS) was used with CARES/Life

    Long-Ranged Correlations in Sheared Fluids

    Full text link
    The presence of long-ranged correlations in a fluid undergoing uniform shear flow is investigated. An exact relation between the density autocorrelation function and the density-mometum correlation function implies that the former must decay more rapidly than 1/r1/r, in contrast to predictions of simple mode coupling theory. Analytic and numerical evaluation of a non-perturbative mode-coupling model confirms a crossover from 1/r1/r behavior at ''small'' rr to a stronger asymptotic power-law decay. The characteristic length scale is λ0/a\ell \approx \sqrt{\lambda_{0}/a} where % \lambda_{0} is the sound damping constant and aa is the shear rate.Comment: 15 pages, 2 figures. Submitted to PR
    corecore